Stopwatch

Block: Stopwatch (stopwatch)
Block Author: Jason Manley
Document Author: Jason Manley

Contents

Summary

Counts the number of clocks between a start and stop pulse.

Mask Parameters

None.

Ports

Port

Dir

Data Type

Description

start

in

boolean

Start counting

stop

in

boolean

Stop counting and hold value until reset received

reset

in

boolean

Reset back to zero.

count_out

out

ufix_32_0

Number of clocks elapsed since start pulse received.

Description

This block counts the number of clocks between a start and stop pulse. This value is held until a reset is received. If another start pulse is received before the reset, counting resumes from where it left-off. If a reset is received mid-way through a count (ie before a stop pulse) then the stopwatch will be reset and await another start pulse before it restarts counting.