Stopwatch
Block: Stopwatch (
stopwatch)Block Author: Jason Manley
Document Author: Jason Manley
Contents |
Summary
Counts the number of clocks between a start and stop pulse.
Mask Parameters
None.
Ports
Port |
Dir |
Data Type |
Description |
|---|---|---|---|
start |
in |
boolean |
Start counting |
stop |
in |
boolean |
Stop counting and hold value until reset received |
reset |
in |
boolean |
Reset back to zero. |
count_out |
out |
ufix_32_0 |
Number of clocks elapsed since start pulse received. |
Description
This block counts the number of clocks between a start and stop pulse. This value is held until a reset is received. If another start pulse is received before the reset, counting resumes from where it left-off. If a reset is received mid-way through a count (ie before a stop pulse) then the stopwatch will be reset and await another start pulse before it restarts counting.